Air may be trapped in the system, especially when operating the roof manually, after replacing one or more
components of the hydraulic system or if the low fluid level is too low. The system is a closed circuit which
is self-bleeding in normal operating conditions. Sometimes, however, manual bleeding may be necessary,
especially after work carried out on the hydraulic system. ALWAYS check for leaks or damage to the
components before working on a system that requires bleeding. If air is found in the system but there are
no other problems, it is NOT necessary to replace any components.
Remove the luggage compartment trim panels (
Remove the rear left hand trim panel only.
Refit the luggage compartment trim panels (
Refit the rear left hand trim panel.
E4.07).
Loosen or hand tighten the filler plug (1) so that
is it fastened to the tank by only two turns of
the relative thread. This allows trapped air to
escape more easily from the tank. Pressure
surges and escaping air can therefore be
released into the atmosphere, preventing
damage to the tank.
Open and close the roof three times and check
that it functions correctly.
Use only the prescribed fluid - Pentosin CHF
11S.
Monitor the fluid level throughout the entire roof
opening and closing cycle: if necessary, top
up the tank to the MAX level with the
specified fluid.
Tighten the filler plug (1).
Tightening torque
Plug
E4.07).
Nm
Class
2 Nm
B