13
PBX EXTEnSIon
Converter Bridge screen
PBX Extension > Converter Bridge
■ Call Initiation Setting
The VoX (voice operated transmission) function automatically switches the connected transceiver to receive,
when the RoIP gateway receives the audio signal from the bridge connection destination device.
Attack Time
������
1
Release Time ������
2
Voice Delay �������
3
VOX Threshold �����
4
1
2
3
4
Enter the TX attack time. It is the delay time before the VoX switch
turns on after an audio signal is received through the network.
• Range: 5 ~ 2000 (milliseconds) in 5 millisecond steps
Select the RX delay time in 5 millisecond step. It is the delay time for
the VoX switch to turn oFF after no audio signal is received through
the network.
• Range: 5 to 2000 (milliseconds) in 5 millisecond steps
Set the audio signal buffer time to prevent intermittent audio.
• Range: 0 ~ 500 (milliseconds) in 5 millisecond steps
Set the voice threshold level. The audio signal is output to the network
according to this threshold level.
• Range: 0 ~ 100 (%)
L The lower values make the VoX function more sensitive to the voice input.