Icom VE-PG4 Operating Manual page 152

Roip gateway
Hide thumbs Also See for VE-PG4:
Table of Contents

Advertisement

6
TRANSCEIvER CoNTRoLLER
Profile screen
Transceiver Controller > Common Settings > Profile
■ Profile
TOT ����������
28
TOT Timer �������
29
Penalty Time ������
30
TOT Beep ��������
31
28
29
30
31
32
33
Select whether or not the IP100H uses the Time-out timer.
L When "Enable" is selected, the [TOT Timer] (29), [Penalty Timer] (30), [TOT
Beep] (31), [TOT on Telephone Call] (32) are displayed.
L This function is useful when the IP100H's PTT switch has accidentally been
held down.
Set the Time-out timer. The timer limits the IP100H's continuous
transmission.
• Range: 11 and 600 (seconds)
L When the period of time has passed, transmitting automatically stops.
Set the TOT Penalty time. After the [TOT timer] (29) period ends, the
TOT Penalty timer starts and inhibits the user from transmitting during
the penalty period.
• Range: 1 ~ 600 (seconds)
Select whether or not the IP100H uses the TOT beep function.
L When "Enable" is selected, a beep sounds 10 seconds before the period of
time that is set in the [TOT Timer] (29) ends.
34
6-81
35
(Default: Disable)
(Default: 180)
(Default: 30)
(Default: Enable)

Advertisement

Table of Contents
loading

Table of Contents