7
CONNECTION PORT SETTINgS
EXT I/O (EXT) screen
Connection Port Settings > EXT I/O (EXT)
■ EXT Input Settings
Input Connection Port
6
6
7
8
9
10
11
12
13
14
15
16
17
Select the port which outputs the received audio signal.
• EXT Output:
• IP Network:
• Emergency:
7-37
Sends the audio signal to the devices that are connected to
EXT1 ~ EXT4 ports.
Sends the audio signal to the devices that are connected
to the RoIP gateway through the IP network.
Sends the audio signal to the device that is specifi ed as
the emergency call destination in the
"Emergency Notification."
(Expert Settings > Emergency Notification)
L Emergency communication has priority over normal
communication.
L The RoIP gateway enters the Emergency mode when
the option selected in the Input Control (8) of the EXT1
~ EXT4 ports are satisfi ed.
L In the Emergency mode, all ongoing communication
routes, other than that for the Emergency Notice, are
disconnected.
L To transmit the call as the Emergency Notice:
• Confi rm the "Bridge Communication Source" is set to
"Emergency Notification."
(Bridge Connection Settings > Bridge Connection >
Bridge Connection > Bridge Connection Source)
• Confi rm the "Bridge Communication Destination" is set
to "Custom Bridge Connection."
(Bridge Connection Settings > Bridge Connection >
Bridge Connection > Bridge Communication Destination)
• Confi rm the "Emergency Notification Equipment" is set
to "Enable."
(Expert Settings > Emergency Notifi cation >
Emergency Notifi cation >
Emergency Notification Equipment)
(Default: IP Network)