7
CONNECTION PORT SETTINgS
EXT I/O (EXT) screen
Connection Port Settings > EXT I/O (EXT)
■ EXT Output Settings
Client Mode: Disable
L The screen shows Serial Communication (6) is set to "Enable," and Client Mode (7) is set to "Disable."
12 ~17
are displayed only when the Data Mode (11) is set to "Manual."
L
Client Mode: Enable
L The screen shows Serial Communication (6) and Client Mode (7) is set to "Enable."
Serial Communication
6
Client Mode
7
TCP Port Number
8
Communication Control
9
6
7
8
9
10
11
12
13
14
15
16
17
6
7
18
19
9
10
12
13
14
15
16
20
Select "Enable" to use serial communications.
~
* Items
are displayed when "Enable" is selected.
7
11
Select "Enable" to set the RoIP gateway as the client in serial
communications.
L When Enabling this the Client Mode, enter the Server Address (18) and the
Server Port number (19).
Enter a port number between 1024 and 65535.
(Default: EXT1=50000, EXT2=50001, EXT3=50002, EXT4=50003)
Select the communication type.
L Automatically set to "Full-Duplex" when Switching Control (3) is set to
"Relay Circuit."
7-45
(Default: Disable)
(Default: Disable)
(Default: Full-Duplex)