Icom VE-PG4 Operating Manual page 110

Roip gateway
Hide thumbs Also See for VE-PG4:
Table of Contents

Advertisement

6
TRANSCEIvER CoNTRoLLER
Transceiver Settings screen
Transceiver Controller > Transceiver Settings > Transceiver Settings
■ Transceiver Settings
Key-Touch Beep �����
23
Gain ����������
24
Monitor ���������
25
23
24
25
Select whether or not the IP100H sounds the Key-Touch beep.
When "Disable" is selected, the IP100H does not sound the
confirmation beep when a key is pushed.
• Key-Touch Beep Level
Set the volume level of the notification beeps when the IP100H's key
is pushed.
The selectable range is between 0 and 32.
L When "0" is selected in this setting, the IP100H does not sound any beep,
even if the volume level is set.
L When "Disable" is selected, this setting is grayed out and the volume level
cannot be changed.
Adjust the microphone sensitivity.
• Range: –12 (low) ~ 12 (high) dB, in 3 dB steps.
L When the noise level around the IP100H is high, set to low sensitivity and
speak in a slightly louder voice that makes listening easier. Or when the
noise level around the IP100H is quiet, set to high sensitivity and speak in
smaller voice that makes listening easier.
Select whether or not the IP100H with an earphone microphone uses
the Monitor function.
When this setting is set to "Enable," you can hear your transmit audio
from the earphone. Set the monitor level to between 0 and 32.
L When "0" is set, your voice is not heard from an earphone microphone,
regardless of the audio setting in the IP100H.
L To prevent howling, set this setting to "Disable" when using a speaker
microphone, such as the HM-186LS.
6-39
(Default: Enable)
(Default: 10)
(Default: 0 (dB))
(Default: Disable)
(Default: 10)

Advertisement