13
PBX EXTEnSIon
Transceiver Controller Telephone Connection screen
PBX Extension > Transceiver Controller Telephone Connection
■ Release Timer
Sets the timers for canceling or disconnecting a call.
Call Cancel Timer ����
1
No Voice Release Timer �
2
Forced Disconnect Timer
3
1
2
3
Enter the period of time to cancel the call. When the set time has
passed without a response from the SIP phone, the call is canceled.
• Range: 0 (oFF) or 5 ~ 60 (seconds)
Enter the period of time to stop transmitting. When the set time has
passed with no audio signal, transmitting is stopped.
• Range: 0 (oFF) or 5 ~ 600 (seconds)
Enter the period of time to be forcibly stop transmitting. When the set
time has passed, transmitting is stopped, even when communication is
ongoing.
• Range: 0 (oFF) or 5 ~ 120 (minutes)
13-59
(Default: 15)
(Default: 15)
(Default: 10)