Icom VE-PG4 Operating Manual page 256

Roip gateway
Hide thumbs Also See for VE-PG4:
Table of Contents

Advertisement

9
ExPERT SETTINGS
Call Recording screen
Expert Settings > Call Recording
■ Recorder Setting
L Displayed when Mode (2) is set to "Monitor" or "Monitor + Recording."
Destination Address
5
Destination Port Number
6
Source Port Number
7
Voice Protocol �����
8
<Apply> ��������
9
<Reset> ��������
10
5
6
7
8
��
Enter the IP address of the destination to be monitored.
Enter the port number of the destination to be monitored.
��
Enter the number of the source port that is connected to the
destination to be monitored.
Displays the voice protocol. (Fixed to "G.711u")
Click to apply the settings.
Click to reset the settings.
L You cannot reset after clicking <Apply>.
9-14
9
10
(Default: 1: 25000
(Default: 1: 25000
2: 25002
3: 25004
4: 25006)
2: 25002
3: 25004
4: 25006)