Icom VE-PG4 Operating Manual page 354

Roip gateway
Hide thumbs Also See for VE-PG4:
Table of Contents

Advertisement

13
PBX EXTEnSIon
Converter Bridge screen
PBX Extension > Converter Bridge
■ Connection
Sets the destination device of the bridge connection that connects to the SIP phones
L The screen above is when the Transmission Mode (1) is set to "Multicast".
Transmission Mode ���
1
Destination Address ���
2
Destination Port Number �
3
1
2
3
4
5
6
7
Set the transmission mode on each extension (port) number.
Set an appropriate IP address, depending on the Transmission Mode
(1) setting.
• For Unicast:
• For Multicast:
Set the same port number as the "Source Port number" (4) setting of
the VE-PG4 that works as the Converter Bridge connection Destination.
• Range: An even number from 2 to 65534.
L Do not duplicate other connection port settings.
 The Default port settings in the Unicast mode
PORT
Converter Bridge 1
Converter Bridge 2
Converter Bridge 3
Converter Bridge 4
Converter Bridge 5
Converter Bridge 6
Converter Bridge 7
Converter Bridge 8
Converter Bridge 9
Converter Bridge 10
Set the IP address for the LAn, or the domain name
of the destination, that of up to 63 characters.
Set the same value as the bridge setting of the call
destination.
DEFAULT
24200
Converter Bridge 11
24202
Converter Bridge 12
24204
Converter Bridge 13
24206
Converter Bridge 14
24208
Converter Bridge 15
24210
Converter Bridge 16
24212
Converter Bridge 17
24214
Converter Bridge 18
24216
Converter Bridge 19
24218
Converter Bridge 20
13-61
(Default: Unicast)
(Default: Blank)
(Default: 239.255.255.1)
PORT
DEFAULT
24220
24222
24224
24226
24228
24230
24232
24234
24236
24238

Advertisement