Icom VE-PG4 Operating Manual page 358

Roip gateway
Hide thumbs Also See for VE-PG4:
Table of Contents

Advertisement

13
PBX EXTEnSIon
Converter Bridge screen
PBX Extension > Converter Bridge
■ Control
The settings for the communication control between the RoIP gateway and a Converter Bridge connection
destination.
Prioritized Receive ���
1
PTT Call Cancel on
2
Call Incoming ������
Target Availability Check �
3
Timing of Target
4
Availability Check ����
1
2
3
4
5
6
7
8
9
10
11
Select "Enable" to inhibit a SIP phone from transmitting an RTP signal
while it is receiving an RTP signal from a Converter Bridge connection
destination.
Select "Enable" to cancel the current call if a SIP phone receives
another call from the same Converter Bridge connection destination
while a call is incoming.
Displayed only when the voice protocol setting on the Converter Bridge
is set to "Bridge Protocol" or "Protocol for Transceiver and SIP Phone
connection" in the "AMBE+2 Vocoder Assignment." (Bridge Connection
Settings > Bridge Connection > AMBE+2 Vocoder Assignment >
Converter Bridge 1 ~ 20)
Select whether or not to check the availability of a Converter Bridge
connection destination when a device such as SIP phone linked to this
RoIP gateway makes a call (excluding an emergency call) to it.
If this setting is enabled, the RoIP gateway will stop sending a call to a
linked transceiver when the destination transceiver is busy, or it does
not answer in 5 seconds.
Set when the Target Availability Check (3) will occur.
• After Call:
Checks after a call is established
• Prior to Call: Checks before a call is established
13-65
(Default: Disable)
(Default: Disable)
(Default: Enable)
(Default: After Call)