Icom VE-PG4 Operating Manual page 159

Roip gateway
Hide thumbs Also See for VE-PG4:
Table of Contents

Advertisement

7
CONNECTION PORT SETTINgS
Digital Transceiver (D-TRX) screen
Connection Port Settings > Digital Transceiver (D-TRX)
■ Digital Transceiver Connection
Edit the settings of the Digital transceiver to connect to the RoIP gateway. You can connect a maximum of 4 digital
transceivers to the network.
L The above screen shows an example for connecting the IC-FR5000 (with UC-FR5000 installed) to the Digital
Transceiver 1 (D-TRX1).
L The above screen shows when the Encryption is set to "Enable."
Connected Repeater's Address
1
Connected Repeater's
2
Port Number
Source Port Number
3
Connection Key Code
4
Area Bit
5
Integrator Code
6
1
2
3
4
5
6
7
8
9
10
11
12
13
Enter the UC-FR5000's IP address.
Enter the Connection Receive Port number that is set in the
UC-FR5000. Do not duplicate the other port number.
• Range: 1 ~ 65535
Enter the Local Port number that is set in the UC-FR5000.
Do not duplicate the other port number.
• Range: 1 ~ 65535
Enter the Key Code that is set in the UC-FR5000.
Turn the Area Bit function ON or OFF, according to the UC-FR5000
setting.
Displays the Integrator Code that is set in the UC-FR5000.
System: NXDN-Trunking
(Default: Digital Transceiver 1 (D-TRX1): 41220
Default: Digital Transceiver 2 (D-TRX2): 41221
Default: Digital Transceiver 3 (D-TRX3): 41222
Default: Digital Transceiver 4 (D-TRX4): 41223)
(Default: Default: Digital Transceiver 1 (D-TRX1): 43000
Default: Digital Transceiver 2 (D-TRX2): 43001
Default: Digital Transceiver 3 (D-TRX3): 43002
Default: Digital Transceiver 4 (D-TRX4): 43003)
7-5
(Default: ucfr5000)
(Default: OFF)