7
CONNECTION PORT SETTINgS
Digital Transceiver (D-TRX) screen
Connection Port Settings > Digital Transceiver (D-TRX)
■ Digital Transceiver Connection
Edit the settings of the digital transceiver to connect to the RoIP gateway. You can connect a maximum of 4 digital
transceivers to the network.
L The above screen shows an example for connecting the IC-FR5000 (with UC-FR5000 installed) to the Digital
transceiver 1 (D-TRX1).
L The above screen shows when the Digital Frame Packet (5) and Scrambler
TX CC
(10
) is checked.
Connected Repeater's Address
1
TCP Port Number
2
(Connection Port)
UDP Port Number
3
(Data Port)
Connection Key Code
4
Digital Frame Packet
5
1
2
3
4
5
6
7
8
9
10
11
Enter the UC-FR5000's IP address.
Enter the Connection Receive Port number that is set in the UC-
FR5000. Do not duplicate the other port number.
• Range: 1024 ~ 65535
Enter the Data Receive Port number that is set in the UC-FR5000.
Do not duplicate the other port number.
• Range: 1024 ~ 65535
Enter the Key Code that is set in the UC-FR5000.
Select whether or not to enable the Packet Encryption function,
according to the UC-FR5000 setting.
When you enable the function, enter an 8 digit Common key.
7-9
System: NXDN-Conventional
(11
) are set to "enabled," and Specify
(Default: Digital Transceiver 1 (D-TRX1): 41200
Digital Transceiver 2 (D-TRX2): 41201
Digital Transceiver 3 (D-TRX3): 41202
Digital Transceiver 4 (D-TRX4): 41203)
(Default: Digital Transceiver 1 (D-TRX1): 41220
Digital Transceiver 2 (D-TRX2): 41221
Digital Transceiver 3 (D-TRX3): 41222
Digital Transceiver 4 (D-TRX4): 41223)