SPC4xxx/5xxx/6xxx – Installation & Configuration Manual
Number
1
2
3
4
Anti-Masking PIR configuration
Number
1
2
3
4
5
6
The following table shows the resistance ranges associated with each configuration.
Single EOLs
EOL Type
NONE
SINGLE_1K
SINGLE_1K5
SINGLE_2K2
SINGLE_4K7
© Vanderbilt 2018
Quiescent
Min
Nom
150Ω
(-100%)
700Ω
1kΩ
(-30%)
1.1kΩ
1.5kΩ
(-27%)
1.6kΩ
2.2kΩ
(-28%)
3.1kΩ
4.7kΩ
(-22%)
Description
Tamper
Alarm
EOL 4k7
EOL 4k7
Description
Tamper
Alarm
EOL 4k7
Fault
EOL 2K2
EOL 4k7
Max
Min
300Ω
300Ω
(+100%)
(+100%)
1.3kΩ
23kΩ
(+30%)
2.1kΩ
23kΩ
(+40%)
2.9kΩ
23kΩ
(+32%)
6.3kΩ
23kΩ
(+24%)
86
Wiring the system
Alarm
Nom
Max
N/A
Infinite
N/A
Infinite
N/A
Infinite
N/A
Infinite
N/A
Infinite