Vanderbilt SPC4 Series Installation & Configuration Manual page 313

Table of Contents

Advertisement

SPC4xxx/5xxx/6xxx – Installation & Configuration Manual
ATS
Event
Timeout
Generate
FTC
Re-
queue
Events
Re-
queue
Event
Delay
Re-
queue
Event
Duration
10. Click the Edit Installation Details button to complete the settings to identify the panel to the
RCT operator. See Edit Installation Details on page 321.
11. Click Save and Back to return to the ATS Configuration page. The new ATS displays in the
Configured ATS table.
12. For multiple ATPs, you can use the up and down arrows in the Event Sequence Table to reorder
the ATP sequence.
NOTICE: The ATS Registration ID is automatically generated for an ATS. It uniquely identifies the
panel to the RCT. If you do not know the SPT Account Code, you can commission the panel using
this ATS Registration ID. The CMS operator must also enter this ATS Registration ID at the RCT
(for example, SPC Com XT). See the SPC Com XT Installation & Configuration Manual.
See also
ATS Category Timings on page 403
© Vanderbilt 2018
The amount of time after an event has been raised and not successfully transmitted
before the ATS gives up. Default: 300 seconds.
Select whether the system generates a FTC on an ATS event timeout.
Select this to re-queue events after an ATS Timeout.
Delay after an ATS Event Timeout before the re-queued event is attempted again.
Default: 300 seconds.
Amount of time that the event will be re-queued before the event is deleted. Default:
86400 seconds.