SPC4xxx/5xxx/6xxx – Installation & Configuration Manual
Using Code
**** XA1.ON
****.XA1.ON
**** XA1.OFF
****.XA1.OFF
**** LOG
****.LOG
**** ENGA.ON
****.ENGA.ON
**** ENGA.OFF
****.ENGA.OFF
**** MANA.ON
****.MANA.ON
**** MANA.OFF
****.MANA.OFF
**** O5.ON
****.O5.ON
****.OUTPUT
**** O5.OFF
****.O5.OFF
****.CLR
****.RESTORE
For SMS recognition, output (mapping gate) identification uses the format ONNN, where O stands
for output, and NNN are the numeric placeholders, of which not all are necessary.
(Example: O5 for output 5)
For SMS recognition, X-10 device uses the format: XYNN, where X stands for X-10; Y stands for
the alphabetic identity and NN are the available numeric placeholders. (Example: XA1)
The SMS operates using a standard protocol that is used in SMS telephones. Note that some PSTN
operators do not provide the service of SMS over PSTN. For SMS to operate over PSTN, the following
criteria are required:
Caller ID needs to be enabled on the telephone line.
l
Direct telephone line – not through PABX or other communications equipment.
l
Also note that most Service Providers only allow SMS to a telephone registered in the same
l
country. (This is due to billing issues.)
© Vanderbilt 2018
Using Caller
Action
ID
Where X10 device is identified as
"A1", it is triggered on.
Where X10 device is identified as
"A1", it is triggered off.
Up to 10 recent events are displayed.
ENGA.ON
Enable Engineer access.
ENGA.OFF
Disable Engineer access.
Enable Manufacturer access.
Disable Manufacturer access.
Where output (mapping gate) is
identified as "O5", it is triggered on.
Where output (mapping gate) is
identified as "O5", it is triggered off.
Allows clear alerts by SMS.
207
Engineer programming via the browser
Response
Status of "A1"
Status of "A1"
Recent events
Allow Engineer
Revoke Engineer
Manufacturer status
Manufacturer status
Status of "O5"
For example:
Output O5 on.
l
Output heating on
l
(where heating is the
name of the output).
Status of "O5"
For example: Output O5 off
A6V10276959-d
12.09.2018