Vanderbilt SPC4 Series Installation & Configuration Manual page 216

Table of Contents

Advertisement

SPC4xxx/5xxx/6xxx – Installation & Configuration Manual
2. Configure the WPA using the following details:
Description
Transmitter
ID
Supervise
Test
Assignment
of Functions
to Buttons
3. Click the Save button to save the settings.
See Also
Changing wireless settings on page 230
l
Triggers on page 292
l
Edit a WPA
To edit a WPA:
1. Select Configuration > Hardware > Wireless > WPA and click the Edit button beside the WPA
you want to edit.
2. The Configure Wireless Personal Alarm (WPA) page is displayed for the WPA.
3. Edit the necessary fields.
4. Click the Save button to save the changes. Alternatively, click the Back button to return to the
previous without saving the changes.
© Vanderbilt 2018
Enter a description or name to uniquely identity a WPA.
Enter the Transmitter ID that is printed on the casing of the WPA.
Alternatively, press any button on the WPA and click the Learn button.
The Transmitter ID field is automatically populated.
You can configure the WPA to send periodic supervision signals. Supervision
is enabled on the WPA with a jumper.
For correct supervision operation, enable the supervision function on the panel
for the particular WPA. If the panel does not get a supervision signal, it raises
an alarm that is shown in the keypad and logged.
If supervision is not enabled, the WPA transmits the battery status to the panel
about every 24 hours. The message is also randomized to decrease the
chances of collision with other WPAs.
Tick the Supervise box to enable supervision for the WPA.
Tick the Test box if a periodic WPA test is required. The timeframe for periodic
testing is configured on the Changing wireless settings page (see Changing
wireless settings on page 230).
Use this section to assign functions to button combinations. Available
functions are Panic, Panic silent, Holdup, Suspicion, RF User Output and
Medical. More than one combination can be selected for the same function.
The defaults for a Financial installation are:
Yellow - Suspicion
l
Red + Green - Holdup
l
For Commercial or Domestic installations, the default is:
Red + Green - Panic
l
Note: If no function is assigned to a button combination, it is still possible to
use that combination by using a trigger. See Triggers on page 292.