SPC4xxx/5xxx/6xxx – Installation & Configuration Manual
System
Restriction
Option
Outputs in Eng
Mode
Alarm on
Reporting Fail
Retrigger
Duress
Retrigger Panic
Override
Reader Profile
Silence Audio
Verification
Watchdog
Output Mode
© Vanderbilt 2018
Description
If selected, the following are not deactivated in Full Engineer mode:
Controller outputs
l
Expander outputs
l
Indicator LEDs
l
Keyswitch LEDs
l
If a 'Fail to Communicate' alert is raised, external bells will activate.
If enabled, duress alarm will retrigger.
If enabled, panic alarm will retrigger.
If enabled, the LED behavior of readers will be controlled by the panel.
If enabled, then the internal and external bells (system and area), the keypad
buzzers and annunciation messages on the Comfort Keypad will be silenced
during audio verification.
Enables output 6 on the SPC controller board to be used for monitoring
purposes. The following modes of operation of the watchdog output can be
selected:
Disable — Output 6 is available as a general purpose output.
l
Enabled — Output 6 is normally OFF but is turned ON when a watchdog
l
fault occurs.
Pulsed — Output 6 is PULSED at 100ms intervals.
l
Enabled Inverted — Output 6 is normally ON but is turned OFF when a
l
watchdog fault occurs.
The following options combine the Enabled option with hardware-fault reporting
in the event of a main microprocessor failure. If such a failure occurs, a SIA
event is sent to ARC1.
Note: The ARC must be configured to use SIA and SIA Extended 1 or 2. CID
and FF are not supported by this reporting method.
Enabled + Reporting (10s) — The failure event is sent to ARC1 10
l
seconds after the fault is detected. This option must be used to comply
with VdS 2252.
Enabled +Reporting (60s) — The failure event is sent to ARC1 60 seconds
l
after the fault is detected.
The SIA event reported is HF and Extended SIA reports Hardware Fault.
Note: Hardware faults are not reported if the Engineer is logged in to the
system.
For more information on ARCs, see Alarm Reporting Centres (ARCs) on
page 329.