3. Save the file with the default filename export_flexc.cxml or rename the file.
4. To view the file, open in Notepad.
5. To import an ATS into the system, go to Communications > FlexC > FlexC ATS.
6. Scroll down to Import ATS.
7. Click the Browse button and select an ATS to import (.cxml file extension).
8. Click Import ATS.
The ATS displays in the Configured ATS table with the next available ID.
When you export an ATS, the SPT Account Code changes to 0. This prevents an ATS being
exported and then imported and replicating an existing ATS.
17.11.2.6 Configuring Event Profiles
The event profile defines which events are transmitted on an ATS, the reporting status for an event and
event exceptions. Event exceptions allow you to remap default values for events to customised
values. For more information, see Event Exception Definition on the next page.
To see a list of all events, go to Communications > FlexC > Event Profiles. Click the Edit icon
for an event profile. Scroll to the end of the page and click Show Complete Event Table.
To quickly create a new event profile, go to Communications > FlexC > Event Profiles. In the
Event Profiles table, select an event profile and click the Edit icon. Scroll to the bottom of the
page and click Replicate. You can now make the changes you require.
1. To configure FlexC event profiles step by step, go to Communications > FlexC > Event
Profiles.