Vanderbilt SPC4 Series Installation & Configuration Manual page 202

Table of Contents

Advertisement

SPC4xxx/5xxx/6xxx – Installation & Configuration Manual
User
Profile
Right
Type
Default
Isolate
Standard*
Manager
User Rights - System
Web
Standard*
Access
Manager
View Log
Standard
Manager
Users
Manager
SMS
Standard*
Manager
Set Date
Standard
Manager
Change
Standard
PIN
Manager
View
Standard
Video
Manager
Chime
Standard
Manager
Engineer
Manager
Upgrade
Manager
User Rights - Control
Outputs
Standard
Manager
© Vanderbilt 2018
Description
Isolating a zone deactivates that zone until such time as the zone is de-isolated. All
zone types on the controller can be isolated.
Use of this feature to deactivate faulty or open zones should be considered carefully;
once a zone is isolated, it is ignored by the system and could be overlooked when
setting the system in the future, compromising the security of the premises.
User can access panel through web browser.
This menu option displays the most recent event on the keypad display. The event
log (see Event Log on page 167) details the time and date of each logged event.
User can create and edit other users on the panel but with only the same or less rights
than this user.
This feature allows users to set up the SMS messaging service if a modem is
installed on the system.
Use this menu option to program the time and date on the system (see Set Date/Time
on page 170).
Ensure the time and date information is accurate; these fields are presented in the
event log when reporting system events.
This menu option allows users to change their user PINs (see Change Engineer Pin
on page 168).
Note: To comply with INCERT approvals, the user's PIN code must contain more
than 4 digits.
User can view video images via the web browser.
Note: The Web Access right must also be enabled for this function.
All zones that have the CHIME attribute set generate a short burst of audible tone on
the keypad buzzer when they are opened (while the system is unset).
This menu option allows for enabling or disabling of the chime feature on all zones.
This option allows users to grant access to engineer programming.
For Swiss CAT 1 and CAT 2 regional requirements, when Engineer Access is
granted, all areas must be unset otherwise the engineer will be denied access.
User can grant manufacturer access to panel to perform firmware upgrade.
User can activate/deactivate configured outputs (mapping gates). See Editing an
output on page 233.
202
Engineer programming via the browser
A6V10276959-d
12.09.2018