SPC4xxx/5xxx/6xxx – Installation & Configuration Manual
Zone attribute
Description
Inhibit
When the 'Inhibit' attribute is set, a user may inhibit this zone. The inhibit operation will disable that
fault or zone for one setting period only.
Normal Open
When the 'Normal Open' attribute is set, the system expects that a connected detector/sensor is a
Normally Open device (for example, a sensor is deemed to be activated whenever the contacts are
closed on the device ).
Silent
If the 'Silent' attribute is set then there will be no audio or visual indications of the Alarm. The alarm
activation will be sent to the Receiver station. If the system is unset then a warning message is
shown on the display.
Log
If this attribute is set then all zone state changes are logged.
Exit Open
If set then zone will be indicated if open during setting.
Frequent
This attribute only applies to remote services*. If this attribute is set for a zone, the zone must open
for remote service purposes within the defined frequent time period.
End of Line
The End Of Line (EOL) attribute provides a number of input zone wiring configurations on the
system.
Analysed
The Analysed Attribute must be set for a zone if that zone is wired with an inertia sensor. The Pulse
count and Gross attack values should be programmed for each inertia sensor on the system in
accordance with the results of a simple calibration of the device.
Pulse Count
Pulse count trigger level for analysed inertia sensors.
Gross Attack
Gross attack trigger level for analysed inertia sensors
Final Exit
The Final Exit attribute can only be assigned to an Entry/Exit Zone type. Use this attribute to
override the standard process of counting down the exit timer whenever the system is full set.
When all other entry/exit routes in the premises are closed, fullset the system and close the final
exit/entry zone. As soon as the door is closed the Final Exit time will count down to setting the
system.
Shunt
A zone with the shunt attribute set will be inhibited whenever a shunt type zone is opened. This
provides a mechanism to group the inhibition of zones with the opening of the shunt zone type.
Report Only
This attribute only applies to the FIRE zone type. If this attribute is set, then activation of the fire
zone will only report the activation to the central station. No alarms will be generated on site.
Open Only
This attribute only applies to the KEYARM zone type. If set then the setting state of the building will
toggle on openings only.
Fullset Enable
This attribute only applies to the KEYARM zone type. If this attribute is set then zone activation will
Fullset the system/area. Apply this attribute if it is intended that the user should only have the ability
to FULLSET the system from a keyarm zone.
Unset Enable
This attribute only applies to the KEYARM zone type. If set then zone activation will Unset the
system/area. Apply this attribute if it is intended that the user should only have the ability to UNSET
the system from a keyarm zone.
Tech Zone
Allows a zone when opened, regardless of the mode to send an alarm to the ARC in FF, CID, SIA
Report
and SIA extended. When areas are selected, the alarm will only be sent to the ARC to which the
area has been assigned to. This would be a "UA" Unknown Alarm followed by the zone number and
text if SIA extended is selected. It will also send an SMS to the end user and engineer if select to do
so when the unconfirmed alarm filter is selected.
© Vanderbilt 2018
391
Appendix
A6V10276959-d
12.09.2018