SPC4xxx/5xxx/6xxx – Installation & Configuration Manual
Protocol
Event Profile
ATP Faults
ATP Monitoring
Fault
Event Timeout
3. Click Save.
© Vanderbilt 2018
Protocol used in communication.
SIA
l
SIA Extended 1
l
SIA Extended 2
l
Contact ID
l
Select the Event Profile which defines how and which events are
transmitted on this ATS.
Use ATS Setting
l
Default Event Profile
l
Default Portal Event Profile
l
All events
l
Custom Event Profile
l
Select to generate an ATP fault if the ATP monitoring fails or an event fails
to transmit on the ATP.
The amount of time that the ATP will keep trying to transmit the event until
the event fails on the ATP and is passed to the next ATP. Default: 2
minutes.
30 seconds
l
60 seconds
l
90 seconds
l
2 minutes
l
3 minutes
l
5 minutes
l
10 minutes
l
320
Engineer programming via the browser
A6V10276959-d
12.09.2018