SPC4xxx/5xxx/6xxx – Installation & Configuration Manual
Exit time
The time (in seconds) allowed for a user to leave a protected area before setting is complete. The
exit time will be counted down at the keypad as the buzzer beeps to indicate to the user that the
system will arm when the exit timer reaches zero. The exit time applies to all entry/exit zones in
that area (default: 45 seconds).
Disable Exit
Select if no exit timer is required and setting is activated by 'Exit term' zone or 'Entry exit' zone with
Time
'Final exit' attribute. See Timers on page 264.
Fob Unset
FOB will only unset when entry timer is running. Default is enabled.
Entry
Access
Access is temporarily denied to the area for the amount of time specified in the Lockout Post Alarm
Denied on
timer.
Alarm
Prevent
If enabled, setting prevented from keypad
Setting
Prevent
If enabled, unsetting prevented from the keypad.
Unsetting
Setting
Used for configuring Blocking Lock operation. Options are:
Authorisation
Disabled
l
Set
l
Unset
l
Set and Unset
l
If the Disabled option is selected (default) then the system will set and unset normally with no
change of operation.
If the Set option is selected, a "Setting Authorisation" signal is required to set this area which can
be received from keypads or a zone input (see Authorised Setting of the Blocking Lock) The user
cannot set the system from the keypad. Any area that requires setting authorisation will appear as
locked on the comfort keypad and will not appear on the standard keypad when setting.
If the Unset option is selected, the user cannot unset the area from keypads but can use the
keypad to generate the setting authorization signal.
For the set and unset options, the user will be unable to change the state of the area at any stage
from the keypad.
A timer for setting authorisation can be configured. See Timers on page 264.
Partset Options
Configure the operation of particular zones for both Partset A and Partset B modes as detailed below:
Partset
Enable PartSet for A and B operation as required.
Enable
Partset
Tick the relevant checkbox (Partset A or B) to apply the exit timer to the Partset A or B mode.
Timed
© Vanderbilt 2018
275
Engineer programming via the browser
A6V10276959-d
12.09.2018