Vanderbilt SPC4 Series Installation & Configuration Manual page 318

Table of Contents

Advertisement

SPC4xxx/5xxx/6xxx – Installation & Configuration Manual
Event
Timeout
Minimum Message Lengths
Poll
Message
Event
Message
Other
Message
3. Click Save.
Add ATP to Analog ARC
If a connection between the SPC panel and RCT (for example, SPC Com XT) goes down, FlexC has the
ability to switch to a backup ATP connection between the SPC panel and an Analog ARC. You can
configure up to 10 ATPs for each ATS.
1. To configure an ATP between an SPC panel and an Analog ARC, click the button Add ATP to
Analog ARC.
2. Complete the ATP fields described in the table below.
Panel Identification
© Vanderbilt 2018
The amount of time that the ATP will keep trying to transmit the event until the
event fails on the ATP and is passed to the next ATP.
30 seconds
l
60 seconds
l
90 seconds
l
2 minutes
l
3 minutes
l
5 minutes
l
10 minutes
l
Minimum length of a poll message.
0 Bytes
l
64 Bytes
l
128 Bytes
l
256 Bytes
l
512 Bytes
l
Minimum length of an event and test call message.
0 Bytes
l
64 Bytes
l
128 Bytes
l
256 Bytes
l
512 Bytes
l
Minimum length of connection and encryption key and update messages.
0 Bytes
l
64 Bytes
l
128 Bytes
l
256 Bytes
l
512 Bytes
l
318
Engineer programming via the browser
A6V10276959-d
12.09.2018