SPC4xxx/5xxx/6xxx – Installation & Configuration Manual
1. To configure an ATS, go to Communications > FlexC > FlexC ATS.
2. Choose from one of the following options:
Add Single Path ATS
l
Add Dual Path ATS
l
Add Dual Path Dual Server ATS
l
Add Custom ATS
l
3. For an EN50136 ATS, you must configure the settings on the ATP Configuration - EN50136 page
first. See Quick Start ATP Configuration for EN50136 ATS on page 309.
4. The ATS Configuration page displays. An EN50136-1 ATS will display a primary or primary and
backup ATP in the Event Sequence Table.
5. Enter an ATS Name to identify the ATS. If you do not enter a value, the ATS name defaults to ATS
1, ATS 2, etc.
6. To add 1 primary and up to 9 backup ATPs to an ATS, click Add ATP to FlexC RCT (see Add ATP
to FlexC RCT on page 314) or click Add ATP to Analog ARC (see Add ATP to Analog ARC on
page 318).
7. Select an Event Profile from the dropdown menu. To customise how events are transmitted on an
ATS, see Configuring Event Profiles on page 323.
8. Select a Command Profile from the dropdown menu. To customise the commands enabled for an
RCT to control a panel, see Configuring Command Profiles on page 327.
9. Complete the ATS Faults fields as shown in the table below.
ATS
Polling
Timeout
© Vanderbilt 2018
This field is automatically calculated by adding the values of the Active Polling
Timeout column in the Event Sequence Table, that is, for all ATPs in an ATS. You
can manually overwrite this field. For example, CAT 2 [Modem] has an Active
Polling Timeout of 24 hours 10 minutes (87000 seconds). To allow a shorter
reaction time, enter a lower value.
312
Engineer programming via the browser
A6V10276959-d
12.09.2018