Vanderbilt SPC4 Series Installation & Configuration Manual page 281

Table of Contents

Advertisement

SPC4xxx/5xxx/6xxx – Installation & Configuration Manual
Area Triggers
The Triggers section is only displayed if triggers have been defined previously. (See Triggers on
page 292.)
Click the Edit button to add, edit or delete trigger conditions for the area.
The following page is displayed:
Configure the trigger for the area using the following parameters:
Trigger Select a trigger from the drop down list.
Edge
The trigger can activate from either the positive or negative edge of the activation signal.
Action
This is the action that is performed when the trigger is activated. Options are:
Unset
l
Partset A
l
Partset B
l
Fullset
l
Delay autoset
l
This action will delay alarm setting when the autoset timer is running. The trigger will only add time
if the Delay Limit has not been exceeded and each trigger activation will delay setting by the time
defined in Delay Interval (see Setting/Unsetting on page 279).
Restore alarms
l
This action will clear all alarms in the configured zone.
Note: Triggers cannot be configured from a keypad.
See also
Triggers on page 292
17.10.4.3 Editing a door
1. Select Configuration > Doors.
A list of configured doors is displayed.
2. Click the Edit button.
3. Configure the fields as described in the tables below.
Door inputs
Each door has 2 inputs with predefined functionality. These two inputs, the door position sensor and the
door release switch can be configured.