Setting
Description
Areas
Select which areas can be controlled through keypad.
Options
Delay
Select to configure a delayed set across all keypads. The location of the keypad is ignored and all
Fullset
areas will perform a full exit time count down.
NOTICE: An area should be assigned to a keypad only if the keypad is inside the assigned area, and
if an entry/exit route is defined. If an area is assigned, when the particular area is set or unset then
entry and exit timers are used (if configured). Other features related to entry/exit routes also become
available. If no area is assigned, the area is set or unset immediately and other entry/exit features are
not available.
Comfort Keypad Settings
Configure the following settings for the comfort keypad.
Setting
Description
Description
Enter a unique description to identify the keypad.
Function Keys (in idle state)
Panic
Select Enable, Disable or Enabled Silent. If enabled, panic alarm is activated by pressing F1 and
F2 soft keys together.
Fire
Enable to allow fire alarm to be activated by pressing F2 and F3 soft keys together.
Medical
Enable to allow medical alarm to be activated by pressing F3 and F4 soft keys together.
Fullset
Enable to allow Fullset to be activated by pressing F2 key twice.
Partset A
Enable to allow Partset A to be activated by pressing F3 key twice.
Partset B
Enable to allow Partset B to be activated by pressing F4 key twice.
Verification
If you assign a verification zone to the comfort keypad, when a Medical, Panic or Fire event is
triggered, or if a user enters a duress code, then audio and video events are activated.
Visual indications
Backlight
Select when keypad backlight is on. Options are: On after key is pressed; Always on; Always off.
Backlight
Select the intensity of illumination of the backlight. Range 1–8 (High).
Level
Indicators
Enable or disable the LED's on the keypad.
Setting state
Enable if setting state should be indicated in idle mode. (LED)
Logo
Enable if logo should be visible in idle mode.
Analog
Select position of clock if visible in idle mode. Options are Left Aligned, Center Aligned, Right
Clock
Aligned or Disabled.
Emergency
Enable if Panic, Fire and Medical function keys should be indicated in the LCD display.