SPC4xxx/5xxx/6xxx – Installation & Configuration Manual
SUPERVISION
The WPA may be configured to send periodic supervision signals. If supervision is enabled on
the WPA (with the jumper), the WPA sends out a supervision message about every 7.5
minutes. The time between messages is randomized to decrease the chances of collision with
other WPAs.
The supervision function must be enabled on the panel for the particular WPA for correct
supervision operation. If the panel does not get a supervision signal, it raises an alarm that is
shown in the keypad and logged.
If supervision is not enabled, the WPA sends out a supervision message about every 24 hours
to transmit the WPA battery status to the panel. The message interval is randomized to
decrease the chances of collision with other WPAs.
Select ENABLE if supervision has been enabled for that particular WPA.
TEST
Enables testing of the WPA signal.
See also
Triggers on page 292
l
Wireless on page 140
l
WPA Test below
l
WPA Test
NOTICE: The test can only be performed by an engineer or a user that has a WPA Test right
assigned to them. See User rights on page 201.
To test the WPA from the keypad:
1. Scroll to TEST > WPA TEST and press OK.
2. When prompted with ACTIVATE WPA, press the three buttons on the WPA simultaneously.
If the test succeeds, a WPA n OK message is shown, where n is the number of the WPA being
tested.
3. Repeat the test if required.
4. Press BACK or X to end the test.
16.9.2.3 IPAW6-10 personal alarm button
The IPAW6-10 personal alarm button is a device that is used to transmit Panic Alarm messages to the
SPC system.
The user can wear the IPAW6-10 in one of two ways:
IPAW6-10 can be worn as a wrist watch (by inserting the wrist band into the two slits of the
l
appropriate ring holder).
IPAW6-10 can be worn as a pendant by removing the wrist ring holder and replacing it with the
l
pendant ring holder.
Enrol a IPAW6-10 personal alarm button
To enrol the IPAW6-10 and assign it to User(n):
1. Select USERS > EDIT > USER(n) > RF FOB > ENABLED.
The keypad displays the ADD screen with a flashing ENROL DEVICE message.