SPC4xxx/5xxx/6xxx – Installation & Configuration Manual
To create a door lock:
1. Create a Door Group. See Editing a door on page 281.
2. Set the Interlock attribute for the required doors in the group. See Editing a door on page 281.
3. Configure a door output for door interlock operation. This output becomes active for all the doors of
the interlock group whenever a door belonging to the group is open, including the open door itself.
This output could be connected, for example, to a red LED or light to indicate that the door could not
be opened, and if inverted could be connected to a green LED or light.
To configure an output for door interlock.
1. In Full Engineer mode, select Configuration > Hardware > X-BUS > Expanders.
2. In the Expander Configuration page, click the Change Type button for the required output.
3. Select Door as the output type.
4. Select the required door and Interlocked as the output type.
17.10.4.4 Adding an area group
You can use area groups for configuring multiple areas. So the configuration must not be done for every
single area.
Prerequisite
Only if the option (multiple) Areas is activated.
o