SPC4xxx/5xxx/6xxx – Installation & Configuration Manual
ATS
Enter the name of the ATS. If you do not enter a value, the ATS name defaults to ATS 1, ATS 2, etc.
Name
SPT
The number that uniquely identifies the panel to the RCT. Enter 0 if you do not have the SPT Account
Account
Code. In this case, you can commission the panel using the ATS Registration ID. For an EN50136
Code
ATS, the ATS Registration ID is automatically generated when you click Save. The RCT can send
the SPT Account Code to the panel when it is available.
RCT Identification & Backup RCT Identification (Dual Path Dual Server Only)
RCT ID
Enter the RCT ID that uniquely identifies the RCT (for example, SPC Com XT) to the panel. This
must match the value entered in the SPC Com XT Server Configuration Manager tool in the Server
RCT ID field in the Server Details tab. See the SPC Com XT Installation & Configuration Manual.
RCT URL
Enter the RCT URL or IP Address for the RCT server location (for example, SPC Com XT server).
or IP
Address
RCT TCP
Enter the TCP port for the RCT (for example, SPC Com XT). This must be the same value entered for
Port
the field Server FlexC Port in the SPC Com XT Server Configuration Manager tool.
ATP Interface
EN50136
Select the EN50136 ATS Category (SP1-SP6, DP1-DP4). For a description of categories, see ATS
ATS
Category Timings on page 403.
Category
Primary
Select the Primary Interface to apply to the primary communications path from the following:
Interface
Ethernet
l
GPRS: Modem 1
l
GPRS: Modem 2
l
Dial Up Internet: Modem 1
l
Dial Up Internet: Modem 2
l
Backup
For a Dual Path ATS, select the Backup Interface to use for the backup communications path from
Interface
the following:
Ethernet
l
GPRS: Modem 1
l
GPRS: Modem 2
l
Dial Up Internet: Modem 1
l
Dial Up Internet: Modem 2
l
17.11.2.3 Configuring an EN50136-1 ATS or Custom ATS
An ATS comprises an alarm panel, network paths and an RCT (for example, SPC Com XT). It
combines one or multiple paths between an SPC panel and an RCT. You can add up to 10 ATPs to an
ATS.
NOTICE: For an EN50136-1 ATS, the ATS set up sequence starts with configuring an ATP for an
ATS. This provides you with a quick set up feature. See Quick Start ATP Configuration for
EN50136 ATS on page 309.