SPC4xxx/5xxx/6xxx – Installation & Configuration Manual
Timer
Description
External Bells
Duration that external sounders will sound when alarm is activated. (0–999 minutes;
0 = never)
EXT BELL
TIME
External Bell
This will cause a delayed activation of the external bell. (0–999 seconds)
Delay 
EXT BELL
DELAY
Chime
Number of seconds that a chime output will activate, when a zone with chime
attribute opens. (1–10 seconds)
CHIME TIME
Confirmation
Confirm
Note: This option is only available for certain Grade and Confirmation option
combinations. (See Options on page 255 and Standards on page 269.)
CONFIRM
TIME
This timer applies to the alarm confirmation feature and is defined as the maximum
time between alarms from two different non overlapping zones that will cause a
confirmed alarm. (0–60 minutes)
Confirmed
Note: This option is only available for certain Grade and Confirmation option
holdup
combinations. (See Options on page 255 and Standards on page 269.)
This timer applies to the confirmed holdup feature and is defined as the maximum
time between alarms from two different non-overlapping zones that will cause a
confirmed alarm. (480–1200 minutes)
Dialer Delay
When programmed, the dialler delay initiates a predefined delay period before the
system dials out to an Alarm Receiving Centre (ARC). This is specifically designed to
DIALER
reduce unwarranted responses from Alarm Receiving Centres and the constabulary.
DELAY
In the event of a subsequent zone being tripped the dialler delay period is ignored and
the dialler dials out immediately. (0–999 seconds)
Alarm abort
Time after a reported alarm in which an alarm abort message can be reported. (0–999
seconds)
ALARM ABORT
Setting
Setting
Period for which Setting Authorisation is valid. (10–250 seconds)
Authorisation
SETTING
AUTH
Final Exit
The Final Exit time is the number of seconds that arming is delayed after a zone
programmed with the final exit attribute is closed. (1–45 seconds)
FINAL EXIT
Bell on Fullset
Activates the external bell momentarily to indicate a full set condition. (0–10 seconds) 0sec.
FULLSET BELL
Fail To Set
Number of seconds to display fail to set message on keypads (0 until valid PIN is
entered). (0–999 seconds)
FAIL TO SET
© Vanderbilt 2018
118
Engineer programming via the keypad
A6V10276959-d
12.09.2018
Default
15min.
0sec.
2sec.
30min.
480min.
30sec.
30sec.
20secs
7sec.
10sec.