SPC4xxx/5xxx/6xxx – Installation & Configuration Manual
Directives and standards
c) Protective switch (that is, door contact) fitted to the final exit door of the alarmed premises or
area
Connect the switch to the SPC System as follows:
The contact is fitted to the final exit door and is connected to an ENTRY/EXIT zone with a 'Final Exit' 
attribute.
See Zone types on page 385 and Zone attributes on page 390.
A misoperation signal is possible using the alarm abort feature. This is enabled by default.
See Options on page 113 (Keypad) and Options on page 255 (Browser).
d) Digital key
Not supported by SPC.
e) In conjunction with an ARC
This method of setting is supported by using SPC COM XT or other third party ARC software using EDP
commands.
3.5.3.2 Methods of completion of unsetting (BS 8243:2010 - Clause 6.4)
Unsetting methods are complied with as follows:
6.4.1 For all the unsetting methods in the SPC system there is an audible indication to the user that the
system has been unset successfully. This is in the form of a beep sequence from the CIE.
6.4.2 Prevention of entry to the supervised premises before the intruder alarm system (IAS) is
unset:
a) Unlocking the initial entry door causes the IAS to be unset;
Compliance by SPC if KEYARM zone type is used with the UNSET attribute only. This zone type must
not be used for setting.
b) Unsetting the IAS by the user before entering the supervised premises causes or permits the initial entry
door to be unlocked.
Compliance by SPC by unsetting using an access card reader on an entry reader with the UNSET option,
or an input from a third party access system to a KEYARM zone with an UNSET attribute.
6.4.3 Prevention of entry to the supervised premises before all means of intruder alarm
confirmation have been disabled:
a) Unlocking the initial entry door causes all means of confirmation to be disabled
Operation not permitted by SPC.
b) Disabling all means of confirmation by the user before entering the supervised premises causes or
permits the initial entry door to be unlocked
Operation not permitted by SPC.
6.4.4 Opening the initial entry door disables all means of intruder alarm confirmation
Operation not permitted by SPC.
6.4.5 Completion of unsetting using a digital key
a) Operation of a digital key before entering the supervised premises (for example, via radio)
SPC satisfies this clause when the installer installs a PACE reader (for example, SPCK421) outside the
premises.
b) Operation of a digital key after entering the supervised premises from a location as near as practicable
to the initial entry door.
This functionality is provided by use of a PACE reader (for example, SPCK421) near the entry door of a
premises.