2. Configure the fields as described in the table below.
Description
Receiver ID
Protocol Version
VdS 2471
Compatible
Security
Commands Enable
Change User PINs
Encryption Enable
Encryption Key
Virtual Keypad
Live
Streaming/Streaming
Mode
Network (Applies to the Ethernet connection only)
Network Enable
Network Protocol
© Vanderbilt 2018
Edit the name of the EDP receiver. Maximum 16 characters.
Edit the EDP receiver ID. Range is 1 to 999997 (999998 and 999999
are reserved for special purposes)
Select the EDP protocol version to use with this EDP receiver.
Options are Version 1 or Version 2. Version 2 is recommended if
supported by the receiver, as it is a more secure protocol.
(Vds standard only)
If this option is selected then the EDP receiver will enforce the
following settings for that receiver:
8s polling interval
l
TCP protocol enforced
l
TCP retries will fail before 10s (9s approx)
l
EDP event retries are set to 1 independent of the global "Retry
l
Count" setting in "EDP Settings"
FTC will be generated within 20s of network failure.
l
Check this box to allow commands to be accepted from the
receiver.
Check this box to allow user PINs to be changed from a remote
location. This feature is applicable only if commands are enabled
from the receiver.
Check this box to enable encryption on data to and from the
receiver.
Enter a hexadecimal key (max. 32 digits) that will be used to
encrypt the data.
Note: The same key will need to be used at the receiver.
Enables access to the panel with a virtual keypad, that is, a PC
software module that looks and behaves like an SPC keypad. It is
available with the SPC Com client.
Specifies when live streaming of audio and video is available.
Options are Never, Always or Only after an alarm event. Default is
'Only after an alarm event'.
Note: This setting has obvious privacy implications and therefore
should be enabled only where appropriate and subject to local laws
and regulations.
Check this box to allow events to be reported through the network.
Select the type of network protocol for the receiver. Options are
UDP and TCP. TCP is recommended if supported by the receiver.