Vanderbilt SPC4 Series Installation & Configuration Manual page 300

Table of Contents

Advertisement

SPC4xxx/5xxx/6xxx – Installation & Configuration Manual
2. Configure the fields as described in the table below.
HTTP
Enabled
HTTP Port
TLS
Enabled
Telnet
Enabled
Telnet Port
SNMP
Enabled
SNMP
Community
ENMP
Enabled
ENMP Port
ENMP
password
ENMP
change
enabled
17.11.1.2 Ethernet
The Ethernet port on the controller can be configured from both the browser and keypad interfaces. An
Ethernet connection with the SPC controller can be established using a direct connection or a LAN
connection.
1. Select Communications > Communications > Ethernet.
The following page will be displayed.
© Vanderbilt 2018
Tick this box to enable the embedded web server on the panel.
Enter the Port number that the web server is 'listening' on. By default this is set
to 443.
Tick this box to enable encryption operation on embedded web server. By default
this is enabled. With TLS enabled, web pages can only be accessed by using
'https://' prefix before typing the IP address.
Tick this box to enable the Telnet server. (Default: Enabled)
Note: Using Telnet without a comprehensive knowledge can damage the
controller configuration; this should only be used if the user has sufficient
knowledge or is being instructed by someone with such knowledge.
Enter the number of the Telnet port.
Tick this box to enable Simple Network Management Protocol (SNMP). (Default:
Disabled)
Enter the Community ID for the SNMP protocol. (Default : Public)
Tick this box to enable Enhanced Network Management Protocol (ENMP).
(Default : Enabled in Full Engineer)
Enter the ENMP port number (default: 1287).
Enter the password for the ENMP protocol.
Check this box to enable network changes to be made with ENMP protocol.