Vanderbilt SPC4 Series Installation & Configuration Manual page 380

Table of Contents

Advertisement

SPC4xxx/5xxx/6xxx – Installation & Configuration Manual
CODE CID EVENT
300
SYSTEM TROUBLE
301
AC LOSS
302
BATTERY LOW
305
RESET
311
BATTERY FAIL
312
PSU OVERCURRENT
320
SOUNDER
330
SYSTEM PERIPHERAL
TROUBLE
333
EXP FAIL
338
EXP BATT
341
EXP TAMPER
342
EXP AC
344
RF JAM
351
TELCO 1
352
TELCO 2
376
HOLDUP TROUBLE
380
SENSOR TROUBLE
401
OPENCLOSE
406
ALARM ABORT
451
EARLY OPENCLOSE
452
LATE OPENCLOSE
453
FAIL TO OPEN
454
FAIL TO CLOSE
456
EVENT PARTSET
461
CODETAMPER
466
SERVICE
570
BYPASS
601
MANUAL TEST
602
AUTO TEST
607
WALK TEST
© Vanderbilt 2018
DESCRIPTION
PSU fault and restore.
PSU mains fail and restore.
System reset.
PSU battery fail and restore.
PSU internal, external and auxiliary fuse fail and restore.
Bell tamper fail and restore.
PSU fault and restore.
X-Bus cable and node communications fault and restore.
X-Bus node battery fault and restore.
X-Bus tamper and RF antenna tamper alarm and restore.
X-Bus node mains fault and restore.
RF jam fault and restore.
Primary modem fault and restore.
Secondary modem fault and restore.
Unset, post alarm and fullset.
Cancel alarm.
Late to unset.
Late to set.
Partset A and B.
User code tamper.
Engineer mode enabled and disabled.
Zone inhibited and uninhibited, zone isolated and un-isolated.
Modem manual test.
Modem automatic test.
380
Appendix
A6V10276959-d
12.09.2018

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents