SPC4xxx/5xxx/6xxx – Installation & Configuration Manual
Test Call
Mode (Active
ATP)
Encryption (256-bit AES with CBC)
Encryption
Key Mode
Encryption
Password
Reset
Encryption
ATP Profiles
Event Profile
Command
Profile
ATP Faults
ATP
Monitoring
Fault
© Vanderbilt 2018
Select the mode for sending test calls when the ATP is the active ATP.
Test calls Disabled
l
Test call every 10 minutes
l
Test call every 1 hour
l
Test call every 4 hours
l
Test call every 24 hours
l
Test call every 48 hours
l
Test call every 7 days
l
Test call every 30 days
l
Select how the encryption gets updated.
Auto Encryption
l
Auto Encryption with Updates
l
Fixed Encryption
l
Note: Auto Encryption uses the default key and updates it once. Auto
Encryption with Updates changes the encryption key every 50,000 messages
or once per week, whichever comes first.
Optional password used to provide increased security during initial ATP
commissioning. The password must be entered at the SPT or RCT
independently.
Reset the Encryption Key and password to the default values.
Select the Event Profile which defines how and which events are transmitted
on this ATS.
Use ATS Setting
l
Default Event Profile
l
All events
l
Select the Command Profile which defines the commands that are allowed on
this ATS.
Use ATS Setting
l
Default Command Profile
l
Custom Command Profile
l
Select to generate an ATP fault if the ATP monitoring fails or an event fails to
transmit on the ATP.
317