Description
Select the type of event reported resulting from Zone Unstable detection when
the panel is set. Options are: Disabled, Tamper and Trouble.
A zone is unstable if a valid sample cannot be obtained within 10 seconds.
The option can only be configured when the panel is in 'Unrestricted' mode. In
Grade 2 or 3 mode, the type of event reported is in accordance with the
standards for the selected region:
Germany VDS – Tamper
l
All other regions – Trouble
l
Select the End Of Line termination resistors that will apply to either all zones on
the system or new zones added to the system. Select a value to enable the
appropriate feature.
To apply a new EOL setting to all existing zones, select the Update all zones
checkbox. If you change the End of Line value but do not select this checkbox,
the new setting applies only to zones added after changing the value.
If enabled, EOL wide bands are used.
If enabled then WPA* Suspicion alerts have audible and visible indicators on
the keypad (Financial mode only).
If enabled, all seismic sensors in any area that is being set will be tested before
area or system set (Financial mode only).
Enable this feature to automatically restore alerts on the system, that is, when
the open zone that triggered an alarm is closed, a manual restore operation on
the keypad/browser is not required. If disabled it prevents the user from
restoring alerts by resetting the input that triggered the alert.
Enabled: If a non-entry/exit zone is activated during the exit timer countdown,
a local alarm is raised by sounding the bells.
Disabled: If a non-entry/exit zone is activated during the exit timer countdown,
an alarm is not raised.
Note: This option only displays when the Unrestricted grade is selected as
enabling it is not in accordance with EN50131. When you choose the Swiss or
Belgium Region under Standard Compliance Settings, this option is
automatically enabled but it is not visible under Options.
Enabled: If a non-entry/exit zone is activated during the entry timer
countdown, a local alarm is raised by sounding the bells.
Disabled: If a non-entry/exit zone is activated during the entry timer
countdown, an alarm is not raised.
Note: This option only displays when the Unrestricted grade is selected as
enabling it is not in accordance with EN50131. When you choose the Swiss
Region under Standard Compliance Settings, this option is automatically
enabled but it is not visible under Options.
259
Engineer programming via the browser
A6V10276959-d