SPC4xxx/5xxx/6xxx – Installation & Configuration Manual
Output Type
Description
Panic*
This output turns on following activation of panic alarm zone types from any area. A panic alarm
output is also generated if a user duress event is generated or if the panic option for the keypad is
enabled.
Hold-up
This output turns on whenever a zone programmed as a Hold-up type zone triggers an alarm from
any area.
Fire
This output turns on following a fire zone activation on the system (or from any area).
Tamper
This output turns on when a tamper condition is detected from any part of the system.
For a grade 3 system, if communication is lost to an XBUS device for greater than 100s, a tamper
is generated and SIA and CIR reported events will send a tamper.
Medical
This output turns on when a medic zone is activated.
Fault
This output turns on when a technical fault is detected.
Technical
This output follows tech zone activity.
Mains Fault*
This output activates when Mains power is removed.
Battery Fault* This output activates when there is a problem with the backup battery. If the battery voltage drops
below 11V this output activates. The 'Restore' option for this fault is only presented when the
voltage level rises to above 11.8V.
Partset A
This output is activated if the system or any area defined on the system is in Partset A mode.
Partset B
This output is activated if the system or any area defined on the system is in Partset B mode.
Fullset
This output is activated if the system is in Fullset mode.
Fail to set
This output activates if the system or any area defined on the system failed to set; it clears when
the alert is restored.
Entry/Exit
This output activates if an Entry/Exit type zone has been activated; that is, a system or area
Entry or Exit timer is running.
Latch
This output turns on as defined in the system latch output configuration (see Configuring system
latch and auto set outputs on page 239).
This output can be used to reset latching sensors as smoke or inertia sensors.
Fire Exit
This output turns ON if any Fire-X zones on the system are activated.
Chime
This output turns on momentarily when any zone on the system with chime attribute opens.
Smoke
This output turns on momentarily( 3 seconds) when a user unsets the system; it can be used to
reset smoke detectors .
The output will also activate when the zone is restored.
When using the zone to reset latched smoke detectors the first code entry will not activate the
smoke output but will silence bells, on the next code entry if the fire zone is in the open state the
smoke output will activate momentarily. This process is repeatable until the fire zone is closed.
Walk Test*
This output turns on momentarily when a walk test is operational and a zone becomes active.
This output can be used, for example, to activate functional tests of connected detectors (if
available).
Auto Set
This output turns on if the Auto Set feature has been activated on the system.
© Vanderbilt 2018
236
Engineer programming via the browser
A6V10276959-d
12.09.2018