SPC4xxx/5xxx/6xxx – Installation & Configuration Manual
Timer
Description
Strobe on
Activates the strobe on the external bell momentarily to indicate a full set condition.
Fullset
(0–10 seconds)
FULLSET
STROBE
Alarm
Double Knock
The maximum delay between activation's of zones with the double attribute, which
will cause an alarm. (1–99 seconds)
DKNOCK
DELAY
Soak
The number of days a zone remains under soak test before it automatically returns to
normal operation. (1–99 days)
SOAK DAYS
Seismic Test
The average period between seismic sensor automatic tests. (12–240 hours)
Interval
Note: To enable automatic testing, the Automatic Sensor Test attribute must be
SEISMIC
enabled for a seismic zone.
AUTOTEST
Seismic Test
Maximum time (in seconds) that a seismic sensor takes to trigger an alarm in
Duration
response to the 'Seismic Test' output. (3–120 seconds)
SEISMIC TEST
DUR
Auto Restore
Time to delay auto restore after zone state returns to normal. (0–9999 seconds)
Delay
Lockout Post
The duration of time after an alarm before the user can gain access. (1–120 minutes)
Alarm
LOCKOUT
POST ALARM
Access Time
The duration of time the system can be accessed by an alarm access user after the
Lockout Time has elapsed. (10–240 minutes)
External Bell
Duration that the strobe output will be active when an alarm is activated. (1–999
Strobe 
minutes; 0 = indefinitely)
STROBE TIME
Alerts
Mains Delay
The time after a mains fault has been detected before an alert is activated by the
system. (0–60 minutes)
MAINS SIG
DELAY
RF Jamming
The time after RF Jamming has been detected before an alert is activated by the
Delay
system. (0–999 seconds)
© Vanderbilt 2018
119
Engineer programming via the keypad
Default
0sec.
10sec.
14 days
168
hours
30sec.
0sec.
0min.
15min.
0min.
0min.
A6V10276959-d
12.09.2018