Enable this feature to monitor the voltage of the line connected to the modem.
Monitoring
Note: EN 50131-9 Confirmation configuration – In order for EN50131-9 Confirmation to operate
correctly, line monitoring must be enabled. (See Options on page 255.)
Monitoring
Select the period (in seconds) for which the line voltage must be seen as being incorrect before the
Timer
line is deemed by the SPC to be faulty.
Modem
Time delay for a system alert (0–9999 seconds). Default 60 seconds.
Fault Time
SMS
Tick this checkbox to enable the SMS feature on the system.
Enable
Note: The SMS operates using a standard protocol that is used in SMS telephones. Note that
some PSTN operators do not provide the service of SMS over PSTN. For SMS to operate over
PSTN the following criteria is required:
Caller ID needs to be enabled on the telephone line.
Direct telephone line – not through PABX or other comms equipment.
Also note that most Service Providers only allow SMS to a telephone registered in the same
country (this is due to billing issues).
Note: SMS over PSTN is no longer supported. The functionality remains in the product for
backward compatibility.
SMS
Only for PSTN. This number automatically displays the default number for SMS for the country
Server
selected. Enter an appropriate phone number of the SMS service provider that is accessible in
Number
your location.
Automated
Select the timing for automated SMS messages.
SMS
Automated
Enter SMS number to receive automated SMS messages.
SMS
Number
Dial Up Internet Configuration
Dial Up
Select this option to enable the modem to gain internet access through a dial-up connection.
Internet
Enable
Phone
Enter the phone number for the dial-up connection.
Number
Username
Enter the dial-up connection Username.
Password
Enter the dial-up connection Password.
Click the Test SMS button to send a short text message for the purposes of testing the system.
The SMS test is provided only for the purpose of ensuring the SMS feature is operating correctly. A
short text message using alphabetic characters (A-Z) should be used to test this feature.
When using the SMS message feature over a PSTN line, it is necessary to program the phone number of
the SMS service provider that services the area in which the SPC is installed. The SPC system
automatically dials this number to contact the SMS server whenever the SMS feature is activated. Calling
line identity MUST be enabled on the PSTN line for this feature to operate. Each country will have its own
SMS service provider with a unique phone number.