Vanderbilt SPC4 Series Installation & Configuration Manual page 225

Table of Contents

Advertisement

SPC4xxx/5xxx/6xxx – Installation & Configuration Manual
PIR Sensor Pulses Filter
Pet Immunity Filter
PIR Sensitivity
Magnetic contact
To program the attributes for a magnetic contact:
1. Select Configuration > Hardware > Wireless Settings.
2. Click the Edit button beside the desired magnetic contact.
3. Program the attributes.
Programmable attributes for Magnetic contact
Sensor
Description
Sensor Type
Zone
© Vanderbilt 2018
1 Pulse Count – 1 activation will cause an alarm
2 Pulse Count– 2 activations will cause an alarm
3 Pulse Count– 3 activations will cause an alarm
Time Filter Disabled – Any activation will cause an alarm, in particular, the
activation does not need to be present for a pulse duration.
When enabled, will cause the PIR to ignore the motion caused by small animals.
The PIR has 5 sensitivity settings. Select the lowest sensitivity when the
background light levels are changeable.
The number of the sensor as enrolled on the system (1 = first, 2 = second, etc).
Text description of the sensor.
The type of wireless sensor detected (e.g. magnetic contact, PIR).
The zone number to which the sensor has been enrolled.
225
Engineer programming via the browser
A6V10276959-d
12.09.2018

Hide quick links: