Vanderbilt SPC4 Series Installation & Configuration Manual page 174

Table of Contents

Advertisement

SPC4xxx/5xxx/6xxx – Installation & Configuration Manual
Connect
Number
1
2
3
If the SPC Ethernet interface is connected to an existing Local Area Network (LAN), consult the
network administrator for that LAN before connecting to the panel. Default IP Address:
192.168.1.100.
Connect the cable
Connect an Ethernet cable from the Ethernet interface on the PC to the Ethernet port on the
l
controller board
– OR –
If connecting directly from a PC then a cross over-cable must be used. See Network cable
connections on page 367.
The LEDs to the right of the Ethernet interface indicate a successful data connection (right LED on)
and Ethernet data traffic (left LED flashing).
Determine the IP address of the SPC controller
1. Entering the Engineer mode (see Engineer PINs on page 106).
2. Using the up/down arrow keys, scroll down COMMUNICATION option and press SELECT.
3. Scroll to ETHERNET PORT and press SELECT.
4. Scroll to IP ADDRESS and press SELECT.