SPC4xxx/5xxx/6xxx – Installation & Configuration Manual
Editing an input below
l
Editing an output on the facing page
l
Configuring system latch and auto set outputs on page 239
l
X10 Config - Settings on page 240
l
17.10.1.1 Editing an input
1. Select Configuration > Hardware > Controller.
The following page will be displayed.
2. Configure the fields as described in the table below.
Input
End of Line
Analyzed
Pulse
count
Gross
Attack
Zone
Description Enter a text describing the input (max. 16 characters). This text will also appear
Type
Area
Attributes
© Vanderbilt 2018
The number is presented for reference and can not be programmed.
Select the End of Line (EOL) for the zone input (default: 4K7).
Displays if the sensor is an inertia/shock type sensor
Pulse count programmed on the panel that will trigger an alarm from an
inertia/shock sensor.
The Gross attack programmed on the panel that will trigger an alarm from an
inertia/shock sensor
Number of the zone on the panel
on the browser and keypad.
The type of zone (see Zone types on page 385).
Only if (multiple) Areas is activated in menu Panel Settings > System Settings
> Options. Select the areas to which this zone has been assigned.
An icon in this field indicates that attributes have been programmed for this zone
(see Input zones: attributes on the facing page).
232
Engineer programming via the browser
A6V10276959-d
12.09.2018