17.9.1.2 WPA
You can only configure a WPA or check WPA status on the keypad if there is a wireless module
l
fitted on the panel or any of the panel expanders.
A WPA is compatible with SiWay RF Kit (SPCW110, 111, 112, 114 ) only.
l
A WPA is not assigned to a user. Usually, a WPA is shared by several people, for example, security
guards working in shifts. Alternatively a WPA may be permanently attached to a surface such as under a
desk or behind a till.
You can connect up to 128 WPAs per SPC panel.
Configure a WPA
To configure a WPA from the browser, select Full Engineer mode and select Configuration > Hardware
> Wireless > WPA.
The following items can be checked or configured:
Battery Status
l
The panel receives the battery status from the WPA in every frame. The battery status can be either
OK or Low.
Battery monitoring requires a WPA fitted with the PCB revision E-PC138612 or later.
Supervise
l
The Supervise status can be any of the following:
– Fault
The panel has not received a supervision message from the WPA in the period configured in the
Wireless Settings page.
– Disabled
Supervision is not configured.
– OK
Supervision is transmitting normally.
Status
l
The Test Status can be any of the following:
– Overdue
The WPA has not been tested in the period configured in the Wireless Settings page.
– Disabled
Supervision is not configured.
– OK
The WPA test is ok.