Vanderbilt SPC4 Series Installation & Configuration Manual page 249

Table of Contents

Advertisement

SPC4xxx/5xxx/6xxx – Installation & Configuration Manual
Setting
state
Audible Indications
Buzzer
Partset
Buzzer
Keypress
Deactivation
Calendar
Mapping
gate
Keyswitch
PACE
Entry
Areas
Location
Areas
Options
Delay
Fullset
NOTICE: An area should be assigned to a keypad only if the keypad is inside the assigned area,
and if an entry/exit route is defined. If an area is assigned, when the particular area is set or unset
then entry and exit timers are used (if configured). Other features related to entry/exit routes also
become available. If no area is assigned, the area is set or unset immediately and other entry/exit
features are not available.
See also
Calendars on page 287
Editing a Comfort Keypad
1. Select Configuration > Hardware > X-Bus > Keypads.
2. Click one of the comfort keypad identifying parameters.
© Vanderbilt 2018
Select if setting state should be indicated in idle mode.
Enable or disable the buzzer on the keypad.
Enable or disable buzzer during exit time on Partset.
Select if the speaker volume for the key presses should be activated.
Select if the keypad should be limited by calendar. See Calendars on page 287.
Select if keypad should be limited by a mapping gate.
Select if keypad should be limited by a keyswitch.
Tick this box to disable the keys on the keypad during the entry time when a
PACE is configured on the keypad.
Select the secured area where the keypad is located.
Select which areas can be controlled through keypad.
Select to configure a delayed set across all keypads. The location of the keypad
is ignored and all areas will perform a full exit time count down.
249