SPC4xxx/5xxx/6xxx – Installation & Configuration Manual
Setting/Unsetting
The following parameters (with the exception of the Interlock parameter) are only relevant in the
following cases:
A Calendar is selected (see Schedule on page 276), or
l
Unset Duration is enabled (has a value greater than zero), or
l
Both of the above conditions are met.
l
Auto Set
Enter the number of minutes to display a warning before Auto Setting. (0–30)
Warning
Note that the panel sets either at the scheduled time or at the time defined by the Delay Unset
parameter. The first warning is displayed at the configured time before the scheduled time. There
are further warnings starting at one minute before setting time.
Auto Set
Enables the user to cancel Auto Setting by entering a code in the keypad.
Cancel
Auto Set
Enables a user to delay Auto Setting by entering a code in the keypad.
Delay
Keyswitch Enables Auto Setting to be delayed using Keyswitch Expander.
Delay
Enter the number of minutes by which to delay Auto Set. (1–300 )
Interval
Delay
Enter the number of times that Auto Setting can be delayed. (0–99: 0 = unlimited)
Counter
Delay
Enter the number of minutes by which to delay an Unset. (0 = no delay)
Unset
Interlock
Select an Interlock Group to assign to this area. Interlocking only allows one area within the group
Group
to be Unset at any time. Typically used in ATM areas.
Unset
If area is Unset for longer than this it will Set automatically. (Range 0–120 mins: 0 = not active).
Duration
Dual PIN
If this option is enabled, two PINs are required to Set or Unset the area with the keypad. Both
PINs must belong to users who have the required user right for the operation (Setting or
Unsetting).
If the second PIN is not entered within 30 seconds, or it is wrong, then the area cannot be Set or
Unset.
Force Set
Area options for Force-set operation (Normal or Blocked).
Mode
Auto
Check this option to auto-restore closed zones during force-set. If this option is selected, if an alert
Restore
is active or a zone needs to be restored, then it will be automatically restored.
on Force
Set
Late Working Support
An example of using the setting and unsetting parameters is for late working situations where a
calendar has been configured for automatic setting of a premises at a particular time but staff may need
to work late on occasion and the automatic setting needs to be delayed.
Each delay is determined by the amount configured in the Delay Interval parameter, and the Delay
Counter parameter determines the number of times that setting can be delayed. A user needs the
correct value in the Auto Set Delay in order to use this feature.
© Vanderbilt 2018
279
Engineer programming via the browser
A6V10276959-d
12.09.2018