SPC4xxx/5xxx/6xxx – Installation & Configuration Manual
Name
Description
Reader
Displays format of last card used with each configured reader.
formats
(Web)
READER
INFO
(Keypads)
Each free zone number can be assigned to the zones but the assignment is not fixed. If the number '9'
is assigned to a zone, the zone and an input expander with the address '1' is connected to the X-Bus
(which is using the zone numbers 9–16). The assigned zone from the two door controller will be
moved to the next free zone number. Configuration will be adapted accordingly.
Door Groups
The different doors can be assigned to door groups. This is needed if one of the following functionalities is
activated:
Custodian
l
Soft Passback
l
Prevent Passback
l
Interlock
l
Door attributes
If no attribute is activated, a valid card can be used.
Attribute
Description
Void
The card is temporarily blocked.
Door Group Used when multiple doors are assigned to the same area and/or anti-passback, custodian, or
interlock functionality is required.
Card and
Card and PIN are required to gain entry.
PIN
PIN Only
PIN is required. No card will be accepted.
PIN Code
PIN or card are required to gain entry
or Card
PIN to Exit
PIN is required on exit reader. Door with entry and exit reader is required.
PIN to
PIN is required to set and unset the linked area. The card has to be presented before the PIN is
Set/Unset
entered.
Unset
Panel/area will unset, when card is presented at entry reader.
outside
(Browser)