SPC4xxx/5xxx/6xxx – Installation & Configuration Manual
System
Restriction
Option
User Duress
PIN Policy
Door & Reader
Reset Cards
Ignore site code If enabled, the access system will ignore site codes. By ignoring the site code,
Card Formats
Web Only
Door Mode Set
Web Only
Door Mode
Unset
Override
Reader Profile
Engineer
© Vanderbilt 2018
Description
Select one of the following Duress options to activate this function on the
system.
PIN +1(system reserves the PIN before and after the user PIN for duress.
l
PIN + 2 (system reserves two PINs before and after the user PIN for
l
duress.
Duress must be enabled for individual users. See section on Adding/Editing a
User.
Click the Edit button to select options for PIN usage.
Periodic changes required – enforces scheduled changes to the user's
l
PIN. The period is defined in the PIN Valid field of Timers. See Timers on
page 264.
Warn if changes required – generates a user alert if the user's PIN is about
l
to expire, or has expired. The warning period is defined in the PIN
Warning field of Timers. See Timers on page 264.
User selects the last digit – enables the user to select the last digit of their
l
pin. The preceding digits are automatically generated by the system.
User selects the 2 digits - enables the user to select the last two digits of
l
their PIN. The preceding digits are automatically generated by the system.
Limit Changes – limits the number of changes possible within a valid PIN
l
period. This value is defined in the PIN Changes Limit field of Timers.
See Timers on page 264.
Secure PIN - If enabled the PIN will be automatically generated by the
l
panel.
If enabled, access cards passback state will be reset every day at midnight.
you only add the card number and increase the card users on the system from
100 to 2,500.
Click the Edit button to select the card formats that will be allowed on this
panel.
See Supported card readers and card formats on page 394 for details of
currently supported card readers and card formats.
Note: Selecting Wiegand enables all Wiegand card formats.
Select the required user identification to unlock door when area is set. Options
are Default, Card and PIN, Card Or PIN.
Select the required user identification to unlock door when area is unset.
Options are Default, Card and PIN, Card Or PIN.
If enabled, Reader LEDs indicate setting confirmation and Card+PIN request.