SPC4xxx/5xxx/6xxx – Installation & Configuration Manual
Add ATP to FlexC RCT
Add ATP to FlexC RCT allows you to configure an ATP between the SPC panel and the RCT (for
example, SPC Com XT). You can configure up to 10 ATPs for each ATS.
1. Click the button Add ATP to FlexC RCT.
2. Complete the ATP fields described in the table below.
Panel Identification
ATP Sequence
No.
ATP Unique ID
ATP Name
SPT Account
Code
RCT Identification
RCT ID
RCT URL or IP
Address
RCT TCP Port
ATP Interface
© Vanderbilt 2018
This field displays the sequence number of the ATP in the ATS
configuration. Number 1 is primary, numbers 2–10 are backup.
When you save an ATP, the system assigns a unique ID to an ATP. This is
the unique ID of the ATP so it can be recognised by the RCT.
Enter a name for the ATP.
Enter a number to uniquely identify the panel to the RCT.
Enter the number that uniquely identifies the RCT (for example, SPC Com
XT) to the panel. This must match the number entered in the field Server
RCT ID in the SPC Com XT Server Configuration Manager tool.
Enter the URL or IP address of the RCT (for example, SPC Com XT).
Enter the TCP Port that the RCT (for example, SPC Com XT) listens on.
The default is 52000. This must match the value in the field Server FlexC
Port in the Server Configuration Manager tool. See the SPC Com XT
Installation & Configuration Manual.
314
Engineer programming via the browser
A6V10276959-d
12.09.2018