SPC4xxx/5xxx/6xxx – Installation & Configuration Manual
Processing
Zone Type
Category
HOLD-UP ALARM
Hold-up
TAMPER
Tamper
TECHNICAL
Intruder
MEDICAL
Hold-up
© Vanderbilt 2018
Description
This zone type is active on a 24-hour basis and activated via a button. When
a Hold-up zone is activated it will report a Hold-up event, independent of
panel arming mode. The SILENT attribute is set by default therefore the
alarm will be silent. If unset, it will generate a full alarm. All activations are
logged and reported if log attribute is active.
When open in the Unset mode, a Local Alarm is generated but no external
bell will activate. If the system is Full Set, a Full alarm is generated. If the
Security Grade of the system is set to Grade 3 then an engineer code is
required to restore the alarm.
The tech zone controls a dedicated tech zone output. When a tech zone
changes state, the tech zone output will follow. That is:
When the tech zone opens, tech zone o/p triggers on
l
When the tech zone closes, tech zone o/p goes off
l
If more than one tech zone has been assigned, the tech zone output will
remain on until all tech zones are closed.
This zone type is used in conjunction with radio or hardwired medical
switches.
Activation in any mode will:
Trigger the medical digital communicator output (unless Local attribute
l
is set)
Cause the panel buzzer to sound (unless Silent attribute is set)
l
Display the message Medic Alarm
l
386
Appendix
A6V10276959-d
12.09.2018