SPC4xxx/5xxx/6xxx – Installation & Configuration Manual
l
To display the list of configured triggers and actions, select Configuration > Advanced > Cause &
Effect > Cause & Effect List.
The Cause & Effect List page displays only fully functioning cause & effects. For example, if a
mapping gate is not assigned to a trigger or to a quick key, it is not displayed in the list.
WARNING: Your system will not comply with EN standards if you enable a trigger to set the
system without a valid PIN being required.
17.10.7.2 Mapping Gates
Triggers are used with Mapping Gates, which are virtual outputs defined by the user that can be
mapped to a physical output. There can be a maximum of 512 Mapping Gates.
For continuous output, when the trigger is a valid user code, both states must be the same, either
both negative or both positive.
1. Select Configuration > Advanced > Cause & Effect > Mapping Gates.
The following page displays.
2. Enter a Description for the gate. This is important as no mapping gate number, only the
description, is displayed on the Outputs user page for turning on and off gates.
3. Tick the Local check box if you do not want to allow users to turn on and off this gate, even if
they have the right to do so. A local gate is not visible remotely.
4. Select desired Quick Key.
A quick key is a '#' followed by a single digit pressed at the keypad. If a shortcut is configured
and is pressed at the keypad, the user is prompted to turn the output on or off.
There may be many outputs activated by one shortcut, both X-10 and Mapping Gates.
5. Add a Timer for the gate. Time quantity used is 1/10 of a second.
6. Click the Triggers button to configure triggers for turning the output on and turning it off. In both
cases, a positive or negative edge of the trigger needs to be defined. See Triggers on the next
page for details of configuring triggers.
© Vanderbilt 2018
Door: Assign a trigger (virtual input) to trigger door action. Choose a Door from the drop-
down list before you click the Assign button.
291
Engineer programming via the browser
A6V10276959-d